Update of FIT digitizer parameters for 2025 data#2325
Update of FIT digitizer parameters for 2025 data#2325spulawsk wants to merge 5 commits intoAliceO2Group:masterfrom
Conversation
|
REQUEST FOR PRODUCTION RELEASES: This will add The following labels are available |
|
@jackal1-66 The error in the log seems to be related to MFT, so I do not think it comes from this PR. |
|
@f3sch : It appears the ITS-MFT staggering development c9acd57adde in O2 breaks the O2DPG CI. The log says Do we need to change anything in O2DPG? |
This PR updates FT0 and FV0 digitizer settings for Run 3 data (runs 562260–568721) to better reflect 2025 conditions and recent digitizer improvements.
Key changes
FT0 calibration: set to ~14 ADC/MIP (mMip_in_V = 7, updated conversion factors)
System-dependent tuning:
FV0 ADC/MIP: